Twenty Li-ion batteries pulled from an Anker power station that wouldn't start up, appears fine otherwise. Would love them not to go to waste, sadly I don't have time to make something with them.
They are labeled ITR26/70-40E 3.2v 12.8Wh
TESTING PROCESS:
They are labeled ITR26/70-40E 3.2v 12.8Wh
TESTING PROCESS:
- Measure cell original voltage
- Recharge using XTAR VX2 PRO Battery Analyzer / Charger
- Record final voltage
- Wait 2 weeks minimum
- Measure again, calculate voltage drop (data below)
- Set into "Store" mode on XTAR VX2 Pro to preserve cell life
| Cell Original Voltage | Recharge Date | Recharge Voltage | Inspection Voltage | Voltage Difference | Days since recharge | Inspection Date |
| 0.98 | 11/23/25 | 3.51 | 3.34 | -0.17 | 17 | 12/10/25 |
| 0.56 | 11/23/25 | 3.39 | 3.33 | -0.06 | 17 | 12/10/25 |
| 1.03 | 11/19/25 | 3.49 | 3.33 | -0.16 | 21 | 12/10/25 |
| 1.05 | 11/19/25 | 3.50 | 3.32 | -0.18 | 21 | 12/10/25 |
| 1.18 | 11/18/25 | 3.46 | 3.34 | -0.12 | 22 | 12/10/25 |
| 0.56 | 11/24/25 | 3.46 | 3.34 | -0.12 | 16 | 12/10/25 |
| 1.00 | 11/22/25 | 3.39 | 3.33 | -0.06 | 18 | 12/10/25 |
| 1.01 | 11/19/25 | 3.51 | 3.33 | -0.18 | 21 | 12/10/25 |
| 1.04 | 11/19/25 | 3.48 | 3.33 | -0.15 | 21 | 12/10/25 |
| 1.18 | 11/18/25 | 3.53 | 3.33 | -0.20 | 22 | 12/10/25 |
| 0.57 | 11/24/25 | 3.55 | 3.36 | -0.19 | 16 | 12/10/25 |
| 1.00 | 11/22/25 | 3.42 | 3.34 | -0.08 | 18 | 12/10/25 |
| 1.03 | 11/20/25 | 3.44 | 3.34 | -0.10 | 20 | 12/10/25 |
| 1.16 | 11/20/25 | 3.45 | 3.33 | -0.12 | 20 | 12/10/25 |
| 1.18 | 11/18/25 | 3.52 | 3.33 | -0.19 | 22 | 12/10/25 |
| 0.56 | 11/25/25 | 3.48 | 3.35 | -0.13 | 15 | 12/10/25 |
| 1.02 | 11/22/25 | 3.42 | 3.35 | -0.07 | 18 | 12/10/25 |
| 1.03 | 11/20/25 | 3.45 | 3.34 | -0.11 | 20 | 12/10/25 |
| 1.16 | 11/20/25 | 3.40 | 3.33 | -0.07 | 20 | 12/10/25 |
| not recorded | 11/17/25 | 3.43 | 3.33 | -0.10 | 23 | 12/10/25 |