Which fuses can be used for protection in the DC area for two directions

Walde

Member
Joined
May 18, 2018
Messages
131
Which fuses can be used for protection in the DC area for two directions

We are having a little discussion right now.
Which safeguards should best be used for protection. I am currently using Schneider 64A and 32A DC fuses for the PCM60 and the solar strings. And for the 5048 PIP and as backup fuse for the batteries, the TOMZN DC TOB1Z-125 C125 (2P 125A DC 600V).

Now "ajw22" had drawn my attention to the fact that there were apparently fire-dangerous problems when using the DC fuses in two directions.

You can find information about the superstructures and the safety devices and also about the discussion here

https://secondlifestorage.com/showthread.php?tid=5265&page=5

What experiences have you had with securing the batteries and systems.
Or what solutions do you have in use with you.

:huh:

** Please reply here in the thread. **
 
Interesting topic - never gave it a thought before this post. I use Midnite Solar circuit breakers (15, 30, 80, and 250a) for my off-grid solar system + an ABB SACE S5 as main battery shunt-trip. Here's an interesting discussion about Midnite Solar circuit breakers that there is indeed a recommended DC 'direction'.....

https://forum.solar-electric.com/di...in rail breakers,the output of the controller.

However, it sounds like things will work in the reverse direction? but maybe not as well?
 
It sounds like you are referring to a breaker, not a fuse. They are two very different things and one is not a replacement for the other. Where a breaker would fail, a fuse would not.

There are DC and AC breakers, make sure you are looking at a DC breaker.

Tomzn are directional / polarized breakers. Many bi-directional breakers to choose from and in UL 1077 and UL 489, along with the various trip curves for your type of load.

Here is an application guide to bring you up to speed.
https://www.eaton.com/content/dam/e...it-breakers/FAZ-product-guide-pg01101009e.pdf
 
It's not about breakers.
It's about fuse.

And that there are apparently problems with DC fuses when used in two directions as we always have with island systems and batteries.

I have a breaker as a glow fuse with 160A. Or just use ABB SACE S3, S4 or S5 ... as a breaker.

No We seem to have problems with DC fuses that are of interest to everyone because it represents a fire-dangerous safety risk.
 
Walde said:
It's not about breakers.
It's about fuse.

And that there are apparently problems with DC fuses when used in two directions as we always have with island systems and batteries.
The thread you linked is about polarized breakers & in that thread ajw22 actually says fuses are NOT polarized.
I have never heard of directional fuses. I have heard of directional DC breakers.
HRC, automotive & marine fuses are definitely NOT polarized.

Did you have a link to a manufacturer with a polarized fuse product? Or some other links?
 
ajw22 said:
Walde said:
Now "ajw22" had drawn my attention to the fact that there were apparently fire-dangerous problems when using the DC fuses in two directions.

The issue I mentioned is with DC breakers with polarity, not fuses. Idon't know if there even are directional fuses.


There are no polarity with fuses that I've seen but there's AC and DC fuses. All has to do with the way it's designed to make it not arc at high voltages.
 
Now it's getting exciting.

But let's get to the point.

Are they DC breakers or DC fuses?

Schneider C65H-DC C32A(2P 32A DC 250V)
Schneider C65H-DC C63A(2P 63A DC 250V)
TOMZN DC TOB1Z-125 C125A (2P 125A DC 600V)

According to the imprint, they have a characteristic curve "C" and so I understand it should be fuses.
Please correct me if I am wrong. Am open to learn.


"ajw22" showed me videos that make me a little scared and also thoughtful.


ajw22 said:
Just a FYI:
Those TOMZN DC breakers have a polarity ( ie. flow direction of electrons matters), thus are theoretically not suitable for use on batteries that can get charged ordischarged (thus the direction of current flow can switch). It's probably ok in this case, considering you're operating at less than 1/10 the rated voltage. In the worst case, the breaker on tripping will not be able to kill the electric arc inside, and start to catastrophically burn/melt. A little demonstration:



ajw22 said:
Here's another video showing the dangers of wiring a polarized DC breaker thewrong way.

Now,personally, I assume that a polarized DC breaker rated for 600V will work correctly bi-directionally when running at less than 60V. But nobody will guarantee that.
 
Walde said:
Are they DC breakers or DC fuses?

Schneider C65H-DC C32A(2P 32A DC 250V)
Schneider C65H-DC C63A(2P 63A DC 250V)
TOMZN DC TOB1Z-125 C125A (2P 125A DC 600V)

According to the imprint, they have a characteristic curve "C" and so I understand it should be fuses.
Please correct me if I am wrong. Am open to learn.

All of those are breakers.
 
Walde said:
Which fuses can be used for protection in the DC area for two directions
I douse a 100a Renogy ANL fuseon one of my 48v batteries. They also make 20, 30, 40, and 60a...specs:https://www.renogy.com/20a-30a-40a-60a-100a-anl-fuse-set-w-fuse/

* Found a couple of posts that say the 'direction' doesn't matter.
* My Renogy ANL doesnot have an arrowor anything showing a specific direction - and don't see anything in the specs.
* The examples all show the fuse onthe positive wire rather than negative side.

One cool thing about an ANL... is that it can be turned around (in the holder) - so if you find out at some point that it needs to be reversed you won't have to change any wiring.


 
"Fuses" are basically just wires (possibly encased in glass/ceramic/plastic) designed to melt long before anything else in the circuit. Only one time use.

"Breakers" are resettable switches with one or more triggers (eg. overcurrent, thermal, under/over voltage)

at least that's my understanding.
 
Call to everyone !!!

I would suggest that all of your solutions for securing and wiring the inverters and batteries are presented here.

Happy with pictures and videos. :exclamation:

***********************************************************************************

I am currently testing in the workshop.
Have a car battery with 12v and 74A power (cold start power 640A) added and will do a few tests. :cool:



image_iogdnn.jpg


image_dqrpli.jpg


image_lpcshb.jpg


image_vvlxae.jpg


image_vyhuil.jpg


image_ykzifm.jpg


It will be fun ... :D
 
The solution is apparently very simple.
Called Schneider Electric (formerly known as Merlin Gerin) in Germany / Ratingen.
Ratingen is a neighboring town of Solingen and only 30 km away.

I spoke on the phone with specialists for circuit breakers.

For the DC area with two directions, I was advised against using the Schneider C60H-DC.

The following types of emphases: IC60L, IC60H, IC60N for up to 60V (72V) types up to a maximum of 63A
or C120N, C120H for up to 125V and 125A.
With the use of more than 1 pole connection also 2 times volt or more.


Yes. Now people come back who tell me first that the circuit breakers are AC devices.
But please have a look at the catalog and you will see that there is also the approval for DC.
https://www.se.com/de/de/download/document/ZXKACTI9/
https://www.se.com/de/de/download/document/ZXKACTI9/

ABB also has circuit breakers for the DC area, for example. ABB S281 UC

https://search.abb.com/library/Down...LanguageCode=de&DocumentPartId=&Action=Launch
 
OffGridInTheCity said:
Walde said:
Which fuses can be used for protection in the DC area for two directions
I douse a 100a Renogy ANL fuseon one of my 48v batteries. They also make 20, 30, 40, and 60a...specs:https://www.renogy.com/20a-30a-40a-60a-100a-anl-fuse-set-w-fuse/

* Found a couple of posts that say the 'direction' doesn't matter.
* My Renogy ANL doesnot have an arrowor anything showing a specific direction - and don't see anything in the specs.
* The examples all show the fuse onthe positive wire rather than negative side.

One cool thing about an ANL... is that it can be turned around (in the holder) - so if you find out at some point that it needs to be reversed you won't have to change any wiring.

I was hesitation to add a ANL fuse... but now no... an extra layer of protection will not hurt....
Thanks!
 
Fuses are not directional. Breakers can be but dont have to be..

Breaker can not be a fuse....

What you look at in fuses is characteristics . Like what current they blow at and at what rate. A fuse is basically just a thread that burn off.
A breaker is resetable due to that they relese the Contact based on current flowing through a Wire. Thus Making some of Them directional.


Breakers basically have the same definition as fuses since you in your house (as an example) can be swapped between fuses and breakers.
 
Also breakers can have different characteristics, eg:
- rated for AC only
- rated for AC with limited DC
- rated for DC one way
- rated for DC both ways
- different time vs overload curves.
On the DC side, the ones we need in powerwall systems are best if rated for DC both ways & have a medium curve.
On the inverter output side, eg AC distribution board, they should be "normal" AC ones of course.
 
I for one am going with breakers.
I have investigated this pretty heavily and have come up with the ABB S200 series to be my breaker of choice.

They offer all kinds of trip curves and numerouscurrent protection values,125 VDC bidirectional support, and are reasonably priced esp on eBay.
They also offer a shunt trip attachment, which I will be installing on all my breakers, and putting a RED emergency button in a conspicuous location to do an emergency shutdown tripping all the breakers at once. Anything over 63 Amps will be a ABB Sace S3 also shunt tripped.
A complete system shutdown with fuses ,I feel, is time consuming esp in an emergency.

Correct me if I am reading these ABB specs wrong but I believe they are correct.
Wolf

image_nruuoe.jpg
 
I never realised how confusing a relatively simple device can be made to appear.

AC breakers - they use an inline coil with a bit of metal to effectively create a small electromagnet. The breaker is setup like a mousetrap so that the relatively little force of the magnet cen then trip open a contact. The coil and bit of metal work in both directions and the arc is extinguished by the zero volt crossing of AC.

DC Breakers are the same setup BUT they have a magnet near the contact opening to push or pull the arc to make it longer and therefore extinguish itlef. The polarity of the magnet in relation to the current direction is what it is all about because of where the arc is moved.

Fuses - there are two basic types, filled or not. High voltage fuses are fulled with sand or something similar to melt and or create an insulating vapour poccket to extinguish the arc. Low voltage fuses just rely on the wire melting. FUSES ARE NOT DIRECTIONAL.

DC circuit breakers that are not voltage rated for DC or using an AC breaker that is too low a voltage. The contacts do not create a gap large enough and I have personally stood and watched one of my 10A AC breakers arc and start smoking until I switched it off via a second breaker. That was with just 140V.

High current DC breakers have a totally different issue because the fault current curve when you start looking at 125A breakers and alike, your wiring may end up becoming the fuse wire because with C type curve you could end up with 500A for longer than your wire insulation can avoid smoking before the breaker trips.

Fault current handling is a different issue again because vapourising the internals creates a conductive ionised cloud.

AND just because abreaker costs 10x more than a cheap China knock off it does no mean the cheap option is not as safe or reliable. I use TOMZN breakers for below 40A and trust them after burning a few out with experiments and trips. The higher current breakers scare the s**t out of me because I have not managed to trip a 100A breaker yet and that was with burning 10mm2 wire on a short with over 600A. Your battery lead resistance then becomes critical.

This is all domestic / toy stuff. Airblast breakers and HV stuff is quite different.

Oh, and multipole (more than 2) DC breakers are another one that nobody seems to use, when they maybe should be considering them..


daromer said:
Breaker can not be a fuse....

They are when the fault current is way higher than the rating and the breaker is either blown appart or vapourised completely. Just like a fuse... :p


125A Type C breaker fault current of 1000A can take upto 3 seconds to trip the breaker, 1-2 seconds mid time.

The real concern, which nobody really takes note of initially is that an overload of say 200A can take a minute for the breaker to trip. If your battery wiring is near 80% of the rated current relative to the breaker rating then you run the risk of your wiring setting on fire before the breaker trips.

10mm2 wire is rates for 65A. Double up for 130A...... safe for 125A breaker ?

200A fault current for 60 seconds would start to melt the insulation and the real risk is when the insulation gives that this then allows the conductors to short against other conductive parts. Cascade failure by over rating OR more precsely not enough safety margin..
 
Haha yeah thats true completelycharged. :)
 
The bizare situation that a lot of DC battery packs end up with is that the additional wiring resistance avoids the absolute maximum possible fault current occuring and therefore virtually any breaker would work on LV packs. I have only managed to get upto about 18kW out of my pack when trying to trip breakers and that ended up limited by the wiring and not by the battery capability. The cells and pack setup I have is rated for 360kW (10C cells) and fault current should be > 2x that.