(03-14-2019, 02:52 PM)Wolf Wrote:
(03-14-2019, 12:53 PM)100kwh-hunter Wrote: @wolf
If you need extra space, come over to the Netherlands, I have a very nice big shed, you can make youre own corner there.

I am not difficult with rent, 500 cells per month(-:
100kWh
My shipping container will arrive in a month or so.  Big Grin

Wolf

two for me, please. Big Grin
1 kWp in Test
4 kWh battery target - plus Mobile Home battery
Ultra low cost
Electronics ? No clue. Am machinery engineer.
Reply
#42
(03-13-2019, 12:21 PM)Wolf Wrote: .....what I can do is take a random sample of 4 harvested cells of different manufactures and repeat the test. Would you say that is a good start?
(03-13-2019, 01:36 PM)daromer Wrote: I think thats a good start for sure!

OK here are the results of 4 random cells tested 12 times.
It shows me the samsung needs to be binned Big Grin
Other than that the max difference between the testers was 8.87% Personally I think that is an acceptable margin of error.
What do you guys think?
Should I keep on doing these tests?

Wolf
If 18 X 650 = 2200+mAh then we have power! 
May all your Cells have an IR of 75mΩ or less Smile
Last count as of 5/23/2019
Total Number of Cells                          5354
Cells  >80% of Capacity                      3801
Cells <80% of Capacity                       1553
Cells ≥2200mAh & ≥ 80% & ≤75mΩ    2645 (155) to go
For Info Google Drive
Not your average Wolf       
            Cool



Reply
#43
On different aspect  (please correct me if this is not appropriate) - I have been mulling over the long view and wondering how to track degradation in my cells as the 'years' go by.   

Background:
My system is 48v@780ah / 40Kwh.   I need 24kwh (60%) PV array storage in the battery to make sure I don't loose any PV array power to 'battery full'.   The battery bank is a little over 5,000 18650 harvested cells and its 'live' in that it charges/discharges most every day.  

The system automatically turns the inverter(load) on at 52v (3.71v/pack),  will top out at a max charge of 56.4v (4.03v/pack - about 88% SOC), and inverter off is at 47.5v (3.39v/pack - about 28% SOC).    This is a max of 60% DOD in the 88% to 28% range of battery curve - but looks like it will average about 48% with bottom of 28%.


My question:
has been...  how long will this battery bank continue to deliver 24kwh on those max PV array summer days.    5yrs?   10yrs?   20yrs?.     So the key thing I'm interested in (as the years go by) is 'how much capacity' has been lost due to using the batteries.   In theory, once I've lost over 40% of the battery's original capacity - I will no longer be able to get 24kwh out of - even if I charge to 4.2v and inverter off at 3.0v.  

Solution:
To measure this, I've settled on tracking AH/volt discharge after the PV array input has gone to 0 for the day - e.g. to ensure I'm tracking 'pure discharge'.    I'm using Batrium shunt AH and Batrium shunt battery voltage as the input data.  So far (week's worth) the initial numbers show an average of 67ah/volt. I should see this decrease as a loss of battery capability takes place over time - e.g. 67ah/volt should go down to 60ah/volt indicating a 10% drop.

I'm interesting in any comments on how to track battery degradation over time on a live system (e.g. don't want to shutdown a pack or battery to do discharge tests etc).

Thanks for letting me share Smile
Reply
#44
AFAIK, there is no super accurate way to determine battery degradation on a live battery pack. As mentioned in other threads, coulomb counting is a good way to track state of charge, and you can kind of extrapolate degradation based on voltage differences at different states of charge over time. And Wolf will probably tell you that you can probably calculate battery degradation based on the IR of the battery as time goes on (I'd agree with him on that). I think the best way is to periodically fully charge and fully discharge (to 2.8 or 3.0) the whole battery bank and record capacity. Make sure to record ambient temperature, too, as I've noticed that can affect capacity. I can tell you from my limited experience that a periodic full charge and discharge will not have a huge impact on cycle life. As long as you don't stay at 4.2V or 2.8V too long, the impact will be minimal.
100kwh-hunter likes this post
Reply


Who read this thread?
100 User(s) read this thread:
daromer, Sean, mike, Korishan, PAF, jdeadman, The-J-Man, watts-on, Stefaan De Ridder, Chiptosser, BlueSwordM, Geek, SWEwall, Herbi, DarkRaven, SemaJG, ChrisD5710, Oz18650, not2bme, bogptrsn, Jensk, Charly144, djuro, dwarflundgren, Chablis_m, mbrunton, Dala, Crimp Daddy, jonyjoe505, Ibiza, Zvonko000, SilverNodashi, Bubba, Cherry67, Walde, Unleashed, Riplash, Jim Jr., bukvaahmed@gmail.com, Mikethezipper, Sammm, LaserTony, chuckp, emuland-metroman, Chass90, Beholder, Leipi35, djmrush, Shawndoe, Wolf, Bastler_Ro, camthecam, Dallski, Speicher, stevelectric, PaulDane, ajw22, -olivier-, Lordsangreal, kevinjaye, mart1nn, OffGridInTheCity, LEDSchlucker, zoookii, bchur83, Satiriasis, sparkgap, robmich2012@gmail.com, fannel, jmeuk, mpro, kurt13r, bertvaneyken, Overmind, bmx316, mskip, Church1182, beserker786, fleming, intra, rhedbatt, clissolo, winny, Havskum, Bigfoot48, Greenbatt, BarryG, Mike666, gueorgi, mixedbrasil2014, Ebarnett, FishStormEight, piedranet, 100kwh-hunter, Bilabob, fatpeter55, energy_man, MonkeyThink, JBonesaw, dhiraj scout