Repairing where too start

Joost2

Member
Joined
Jun 21, 2017
Messages
117
Hello all,

I have a question. In the past I bought two electrical scooters with dead batteries. Now I have replaced the cells for the same chemistry but one cell is overcharged every time over and over.

Can someone help me solving this issue by tips?

Thank you for you interest!
 
Is the BMS a problem?
Can you Balance charge the cells one time manually and see if it still happens?
 
Thank you for your reply daromer!

I can balance cell for cell but the BMS need too be repaired because it is housed in a case. I have photos but dont know how too upload.


Could you see the photos?


image_flwmbg.jpg

image_tmrgpr.jpg
 
If the pack continuesly goes out of balance it can be 3 things or 2...

1. The BMS have not catched up -> Make an initial manual balance
2. The BMS board is broken -> Change BMS
3. The cells is so off and self discharge/have problems so they go out of balance faster than the bms can balance -> Change cells
 
Its the second one. I can not find a new one so I have too replace the broken ics
 
Back