Small Powerwall in Germany

IronSky

Member
Joined
Jun 12, 2017
Messages
52
Hi,
here are some pictures of my little Powerwall.
Unfortunately, the MPPT solar controller and the 48 volt inverter are still missing:(
The battery has been built in the style of AveRageJoe and Owitte:p
Each cell has 85AH.


image_szlhmk.jpg




image_cviekv.jpg



image_yvrcaa.jpg



image_rphjqd.jpg


IronSky
 
DUDE!!! Love the holders! :D Thats awesome!

Are the bus bars copper tubing, or ground rod?
 
Korishan said:
DUDE!!! Love the holders! :D Thats awesome!

Are the bus bars copper tubing, or ground rod?

They are copper pipes (tubing), 6x1mm oil pipe, were cheaper than copper bars (Ground rod):D
 
That's neat. Cool idea with the cell holders. Good idea with the pipe, I was going to flatten mine, but why? It can be bent, and replace the need for wire altogether. (was lucky enough to score several meters of air conditioning pipe from the side of the road)
 
Which grade of copper tubing is it; L or M?

Type M has a thinner wall
Type L has a thicker wall

The reason I ask is because the Type L will give you better power transmission as there's more metal to carry the power.
 
Very Cool
 
Korishan said:
Which grade of copper tubing is it; L or M?

Type M has a thinner wall
Type L has a thicker wall

The reason I ask is because the Type L will give you better power transmission as there's more metal to carry the power.

i think it is Type L

0.04" 25.4 = 1.016mm

"Type M half-inch pipe has a wall thickness of 0.028 inches while type L is 0.040 inches"

in Germany we don't have type M or L :)
 
I am not sure that it's a great idea to have the copper pipe fixed to the wall without electric insulation ! except if it's a plastic wall
 
Yeah, I suppose in Germany, you only have an option for Type L, due to the cold temps you can get. Maybe here in the states going up north Type M might not even be available.

However, I'm pretty sure if you use refrigerator water tubing, that's Type M, as it's very easy to bend. But then again, that's definitely inside the house and kept well above freezing (one would hope).

Side Note: I think the US should take notes from Germany and install solar panels along their highways/interstates. A good use for the blank space of real estate.
 
cristof said:
I am not sure that it's a great idea to have the copper pipe fixed to the wall without electric insulation ! except if it's a plastic wall

On the wall is no copper tube but 3 AWG copper cable (25mm2). Unfortunately brown in color.

The wall is clad with fermacell plates.
 
Sory, I need to change my glasses..... :)
 
Update:
The batteries now have a cupboard

image_iwiqgy.jpg



image_tmwlmt.jpg



image_qcitef.jpg


And the cables are now in red and black :D


image_kqfwkj.jpg




Bms is ordered and is on the way AliExpress

See you ... :cool:
 
Here is a picture with the masses of the box for the people who are looking for something.



image_salliq.jpg


Hersteller

10,8 x 11,5 x 7,3 cm

In Germany, you can buy the at "Hagebaumarkt", and there they cost 99 cents apiece.

:idea:
 
Why not cut the legs of the fuses so you dont have to do all that bending ?
 
daromer said:
Why not cut the legs of the fuses so you dont have to do all that bending ?

If the legs are longer, they are more flexible and therefore the vitreous does not break as fast as eg AverageJoe. Since I have only one busbar and all fuses are soldered there, quite a lot of power (movement power or so) is transferred to the legs of the fuses when I move something at the busbar.

I hope you understand what I'm trying to say. The small fuses do not break so fast when I fiddle with it :)
 
IronSky said:
I hope you understand what I'm trying to say. The small fuses do not break so fast when I fiddle with it :)

Sounds reasonable :D
 
Back