Hello all,
Cause of some videos on YT I'm now way over enthusiastic about this DIY powerwall thing. It has costed me tons of time to watch them all. Besides that I'm afraid I got infected with this battery virus thing. I don't want to mention the guilty for this all but there names start with H, D and A and they end with HBPowerwall, DIYtechandrepair and Average Joe.
SoI bought a spotwelder on Ali to start practicing my skills but it doesn't work as it should. It makes a few (4 to 6 or so) welds and then the next one gives a big bang with spark and all and the fuse trips. When I try immediately after resetting the fuse it will trip again but when I try next day I can do a few welds again before fuse trips. What can this be?
This is the welder I purchased:
Spot welder
I asked the supplier and he just answered to put a 40A fuse which is easier said than done cause the main fuses in my house are only 25A and the subsequent is 16A. Here in the Netherlands, we have 230V mains so the man is telling me I should fuse for a burst of 40 x 230 = 9.3 kW which sounds ridiculous to me.
What are your thoughts on this?
Rik
Cause of some videos on YT I'm now way over enthusiastic about this DIY powerwall thing. It has costed me tons of time to watch them all. Besides that I'm afraid I got infected with this battery virus thing. I don't want to mention the guilty for this all but there names start with H, D and A and they end with HBPowerwall, DIYtechandrepair and Average Joe.
SoI bought a spotwelder on Ali to start practicing my skills but it doesn't work as it should. It makes a few (4 to 6 or so) welds and then the next one gives a big bang with spark and all and the fuse trips. When I try immediately after resetting the fuse it will trip again but when I try next day I can do a few welds again before fuse trips. What can this be?
This is the welder I purchased:
Spot welder
I asked the supplier and he just answered to put a 40A fuse which is easier said than done cause the main fuses in my house are only 25A and the subsequent is 16A. Here in the Netherlands, we have 230V mains so the man is telling me I should fuse for a burst of 40 x 230 = 9.3 kW which sounds ridiculous to me.
What are your thoughts on this?
Rik